Documentation of UrbanFireXDT
Documentation of UrbanFireXDT
Loading...
Searching...
No Matches
input-description

% Input description

General overview of the input data

  • The simulation requires a sqlite3-database with the structure of the system that should be simulated (default filename is SystemStructure.db).
  • The existing smart meter data of the individual measurement units must be stored in a subfolder called 'SeparatedSmartMeterData' as individual comma-separated values (csv) files.
  • The file name of the CSV files must equal the measurement unit ID (key: list_of_measurement_units.MeUID) as they are defined in the system structure database.

The general structure of the system structure database

The system structure database requires the following tables:

Table name Description
time_indices List of time indices
list_of_substations List of substations
list_of_control_units List of control units
list_of_measurement_units List of measurement units
global_profiles_pv Global PV feedin (normalized)
global_profiles_pv_info Information about how many global PV feedin time series exist per orientation
global_profile_wind Global wind farm feedin (normalized)
global_profiles_heatpumps Global heap pump demand profiles (normalized)
address_data List of all known addresses with yearly energy demand in case of heat pump heating
heat_demand_per_location Information about the heat demand that is converted using gas consumption data (if available)
address_roof_data List of all roof sections of all buildings (with orientation and size)
residual_grid_load Time series of the residual grid load, that is not measured by any smart meter, but still present
electricity_emissions Time series of the CO2 emissions (optional table, is used, if present, otherwise ignored)
electricity_prices Time series of the hourly electricity prices (optional table, is used, if present)

Structure of the smart meter data / csv files

Each smart meter csv file must have the following columns in this order:

Column name Description
TimestepID The id of the time step (key: time_indices.TimestepID)
PowerDemand_kW Reading of the demand in kWh at the given time step
PowerDemandStatus ignored
PowerFeedin_kW Reading of the feed-in in kWh at the given time step
PowerFeedinStatus ignored

Details on the database tables

Documentation of the configuration database in detail

Table time_indices

Column name Type Description
TimestepID INTEGER ID of the timestep, must start with 1 and must be numbered consecutively
UTC_time TIMESTAMP UTC time stamp of the end of the time step (right alignment) in the format YYYY-MM-DD HH:MM:SS
local_time_la TIMESTAMP Local time stamp of the beginning of the time step (left alignment) in the format YYYY-MM-DD HH:MM:SS
local_time_ra TIMESTAMP Local time stamp of the end of the time step (right alignment) in the format YYYY-MM-DD HH:MM:SS
local_time_zone TEXT/VARCHAR(4) Time zone name of the local time as text (might change e.g. through daylight saving time)

Table list_of_substations

Column name Type Description
substation_id INTEGER ID of the substation, may start with 1 and may be numbered consecutively (not mandatory anymore)
substation_name TEXT Name of the substation

Table list_of_control_units

Column name Type Description
UnitID INTEGER ID of the control unit, may start with 1 and may be numbered consecutively (not mandatory anymore)
substation_id INTEGER ID of the substation to which this control unit is connected to [Foreign key]
LocID INTEGER ID of the location where the control unit is located at [Foreign key]
has_cs INTEGER Holds the value 1, iff there is a charging station already connected to this control unit
n_flats INTEGER The number of flats in a building / for a location (estimation or real value)

Table list_of_measurement_units

Column name Type Description
MeUID INTEGER ID of the measurement unit, may start with 1 and may be numbered consecutively (not mandatory anymore)
UnitID INTEGER ID of the control unit to which this measruement unit is assigned [Foreign key]
UnitID INTEGER ID of the control unit to which this measruement unit is assigned [Foreign key]
MeterPointID TEXT Name of the meter point, i.e. MPRN (Meter Point Reference Number in UK) or MELO (Meter Location Number in Germany)
has_demand INTEGER Holds the value 1, iff this measurement unit shows a demand at least at one point in the simulation time
has_feedin INTEGER Holds the value 1, iff this measurement unit shows a feedin at least at one point in the simulation time
has_pv_residential INTEGER Holds the value 1, iff a residential PV installation is connected (exclusivley and not exclusivley) to the measuremt unit
has_pv_open_space INTEGER Holds the value 1, iff an open-space PV installation is connected (exclusivley and not exclusivley) to the measuremt unit
has_bess INTEGER Holds the value 1, iff a battery is connected (exclusivley and not exclusivley) to the measuremt unit
has_hp INTEGER Holds the value 1, iff a heat pump is connected (exclusivley and not exclusivley) to the measuremt unit
has_chp INTEGER Holds the value 1, iff a CHP is connected (exclusivley and not exclusivley) to the measuremt unit
LocID INTEGER ID of the location where the measurement unit is located at [Foreign key]
has_wind INTEGER Holds the value 1, iff a wind farm is connected (exclusivley and not exclusivley) to the measuremt unit
has_evcs INTEGER Holds the value 1, iff a residential EV charging station is connected (exclusivley and not exclusivley) to the measuremt unit
has_public_evcs INTEGER Holds the value 1, iff a public EV charging station is connected (exclusivley and not exclusivley) to the measuremt unit

Table global_profiles_pv

Column name Type Description
TimestepID INTEGER The time step for which the dataset is valid [Foreign key]
PowerFeedin_kW REAL The normalized feed-in value at the given timestep
Orientation TEXT / VARCHAR(2) The orientation of the given feedin value
SameOrientationTimeSeriesIndex INTEGER If there are more time series for one orientation, this number gives the id (starting with 0) of the time series with the same direction

Table global_profiles_pv_info

Column name Type Description
orientation TEXT / VARCHAR(2) The orientation
number_of_ts INTEGER Number of time series for the given orientation

Table global_profile_wind

Column name Type Description
TimestepID INTEGER The time step for which the dataset is valid [Foreign key]
wind_profile_value REAL The normalized feed-in value at the given timestep

Table global_profiles_heatpumps

This table holds the normalized demand values of every heat pump time series in kW. The normalization takes place on an annual level, so that every time series results in a annual demand sum of 1000 kWh / a.

Column name Type Description
TimestepID INTEGER The time step for which the dataset is valid [Foreign key]
ShiftableDemand_kW REAL The normalized demand value of the heat pump demand at this time step that can be shifted in theory
UnshiftableDemand_kW REAL The normalized demand value of the heat pump demand that cannot be shifted
TimeSeriesIndex INTEGER The index of the heat pump time series (important, if there is more than one time series)

Table address_data

Column name Type Description
LocID INTEGER ID of the location (starting with 0)
n_buildings INTEGER Number of buildings (for which geodata is available)
has_residential_buildings INTEGER Holds the value 1, iff the location holds a residential building, and can thus be regarded as residential location
max_volume REAL The volume of the (biggest) building on the given location - used for aproximating the heat demand if no heat demand is given in table heat_demand_per_location

Table heat_demand_per_location

Column name Type Description
LocID INTEGER ID of the location
MeanHeatEnergy_kWh REAL Mean heat demand of the location in kWh per year / mean over all regarded years

Table address_roof_data

Column name Type Description
LocID INTEGER ID of the referenced location [Foreign key]
Area_in_m2 REAL Area of the roof section in square meter
Orientation TEXT / VARCHAR(2) The orientation of the given roof section; for every orientation there has to exist a correspoding time series in the tabel global_profiles_pv

Table residual_grid_load

Column name Type Description
TimestepID INTEGER ID of the timestep, must start with 1 and must be numbered consecutively
P_residual_gridload REAL Residual grid load in kW during time step TimestepID

Table electricity_emissions

Column name Type Description
TimestepID INTEGER ID of the timestep, must have the same alignment as time_indices.TimestepID
emissions_g_kWh REAL CO2eq. emissions of one kWh of electiricty that is taken from the transmission grid

Table electricity_prices

Column name Type Description
TimestepID INTEGER ID of the timestep, must have the same alignment as time_indices.TimestepID
local_price REAL The local (dynamic) price for residential households for a dynamic tariff in Euro/kWh
spotmarket_price REAL The (dynamic) price at the spot market (without vat or taxes) in Euro/kWh