General description of the output files

The simulation outputs multiple files, that are described below. Folders are marked in bold.

File name and level Description
expansion-matrix-abs-values.csv Expansion matrix filled with absolute numbers
expansion-per-cu.csv List the expansion that happens per control unit
parameter-settings-general.txt A complete list of the defined parameters. The values noted there can be changed during a parameter variation.
**no param vari** Output directory if no param variation is selected
  | metrics-per-cu.csv Computed metrics per control unit (like SSR, SCR, NPV, total grid demand, ...) including the concrete parameters for the simulated PV, battery and the charging station component
  | weekly-metrics-per-cu.csv Computed metrics per control unit on a weekly level. See metrics-per-cu.csv for details.
  | XXXX-substation-time-series.csv Time series of the load, wind/o.s. PV feedin, etc. aggregated on substation level
  | substation-detailed-time-series.csv Time series of the additional details on substation level, like residential load (includes feed-in) and demand (only residential grid demand, no surplus feed-in accumulated)
  | parameter-settings.csv Parameter settings for the concrete simulation run (very useful for parameter variations)
  | sim-added-roof-sections-per-cu.csv A list of all sim. added roof sections per control unit
  | substation-detailed-time-series.csv Addition information, aggregated on substation level, that is not contained in the first file
  | build_and_run_info.txt Information on the simulation run and the used program
  | metrics-per-ev.csv Computed metrics per EV
**param vari XXXX** Output directory if a parameter variation is selected
  | build_and_run_info.txt Information on the simulation run and the used program
  | **variation index XXXX** There is one subfolder for every variation combination, the concrete parameters can be found in parameter-settings.csv
  |  | rest of the content see folder no param vari
Optional output per cu: Files only generated if selected by specified command line arguments. See command line parameter --cu-output for details
  | XXXX-CU-time-series.csv Output of all power flows inside the control units in one file
  | **ts-per-cu** Output of all power flows inside the control units in separated files (grouped by substation)
  |  | YYYY-AllCUs-ts.csv
Further optional output: Files only generated if selected by specified command line arguments. See command line parameter --cu-output for details
ev-details.csv Detailed time series for every simulated EV

Detailed description per file

metrics-per-cu.csv and weekly-metrics-per-cu.csv

Column name Description
UnitID The control unit ID of the current record
SCR The self-consumption rate over the complete simulated time span
SSR The self-sufficiency rate over the complete simulated time span
NPV The net-present value (including installation costs) over the complete simulated time span [not in weekly output]
ALR Array-to-load ratio (see Nyholm et al., 2016 in Applied Energy, https://doi.org/10.1016/j.apenergy.2016.08.172) [not in weekly output]
BDR Battery-to-Demand ratio (see Nyholm et al., 2016) [not in weekly output]
RBC Relative battery capacity (see Nyholm et al., 2016) [not in weekly output]
Sum of demand [kWh] The demand sum of electricity demand of the real smart meters and all simulated consumers (heat pump and charging station) in kWh
Sum of MU demand [kWh] The demand sum of the measurement units, i.e., the real smart meters in kWh
Sum of self-consumed e. [kWh] The sum of locally produced and self-consumed electricity in kWh
Sum of PV-generated e. [kWh] The sum of locally produced PV energy in kWh
Sum of grid feed-in [kWh] The sum of electricity that was fed into the grid in kWh
Sum of grid demand [kWh] The sum of electricity that was demanded from the grid in kWh
BS EFC The battery equivalent full cycles (if not battery is simulated, this value defaults to 0.0)
BS n_ts_empty The number of time steps where the battery was empty (if not battery is simulated, this value defaults to 0.0)
BS n_ts_full The number of time steps where the battery was full (if not battery is simulated, this value defaults to 0.0)
BS total E withdrawn [kWh] The sum of electricity that was withdrawn from the battery in kWh (if not battery is simulated, this value defaults to 0.0) - Attention: The battery might not be empty at the end of the simulation procedure
BS total E withdrawn grid-originated [kWh] The sum of electricity that was withdrawn from the battery in kWh like BS total E withdrawn [kWh], but only the amount that originated from prior grid charging
Sum of HP demand [kWh] The sum of demanded electricity of the heat pump in kWh (if no heat pump is simulated, this value defaults to 0.0)
Sum of CS demand [kWh] The sum of demanded electricity of the EV charging station in kWh (if no EV charging station is simulated, this value defaults to 0.0)
Peak grid demand [kW] The peak grid demand in kW over the complete simulated time span
Emissions cbgd [kg CO2eq] The CO2e emissions caused by grid demand including upstream emissions (but no installation emissions for PV panels, battery storage or heat pumps)
Avoided emissions [kg CO2eq] The avioded CO2e emissions caused by local production (and possibly storing) of renewable energy
Actual electricity costs [CU] The actual electricity costs, i.e., Electricity cons. costs [CU] - Feed-in revenue [CU]. Keep in mind that this value might be negative as well
Electricity cons. costs [CU] The total electricity costs for consumption from the grid over the complete simulation horizon in the general currency unit (CU)
Avoided electricity cons. costs [CU] The sum of electricity costs that were saved by local self-consumption over the complete simulation horizon
Feed-in revenue [CU] The summed revenue of feed-in to the grid in the general currency unit (CU)
Sim. PV max P [kWp] The installed power in kW (resp. kWp) of the simulated PV installation, or 0.0 if none is present
Sim. BS P [kW] The installed power in kW of the simulated battery storage system, or 0.0 if none is present
Sim. BS E [kWh] The installed capacity in kWh of the simulated battery storage system, or 0.0 if none is present
n EVs The number of EVs with their home at this given unit
Sim. CS max P [kW] The installed power in kW of the simulated EV charging station, or 0.0 if none is present
Simulated PV Indicates whether this control unit contains a simulated PV installation
Simulated BS Indicates whether this control unit contains a simulated battery storage
Simulated HP Indicates whether this control unit contains a simulated heat pump
Simulated CS Indicates whether this control unit contains a simulated EV charging station
n errors in cntrl Number of error happend in controller optimization (e.g., infeasible optimization problem)
n errors cntrl cmd appl Number of error happend during the application of the control commands in at least one component (e.g., bound violations in heat pump or EV charging station / EVFSM)

In the case of weekly metrics file, an additional column giving the week number (named Week number) is added.

XXXX-substation-time-series.csv

Column name Description
Timestep The time step ID of the current record
Per substation YYYY
   YYYY Active power in kW at substation YYYY
pv_total_generation_kW Sum of total PV generation (regardless of self-consumption) in kW
pv_feedin_expo_kW Sum of feed-in from control units caused by PV installations in kW
bs_total_generation_kW Sum of total battery storage system discharging power (regardless of self-consumption) in kW
bs_feedin_expo_kW Sum of feed-in from control units caused by battery storage systems in kW
chp_total_generation_kW Sum of total CHP power generation (regardless of self-consumption) in kW
chp_feedin_expo_kW Sum of feed-in from control units caused by CHPs in kW
wind_total_generation_kW Sum of total wind power generation (regardless of self-consumption) in kW
wind_feedin_expo_kW Sum of feed-in from control units caused by wind turbines in kW
unknown_total_generation_kW Sum of total power generation (regardless of self-consumption) where the source is unknown or not attributable to any generation technology
unknown_feedin_expo_kW Sum of feed-in from control units in kW where the source is unknown or not attributable to any generation technology
total_demand_wo_BS_SC_kW Total demand of the buildings-energy consumption, the heat pump and the EV charging station over all control units in kW
total_BS_charging_power_kW Total charging power of all battery stroage systems for all connected control units in kW
OverallBatterySOC Mean SOC over all simulated battery storage systems on control unit level
total_load Total active power in kW in the grid

substation-detailed-time-series.csv

The columns of this output follows the following nomenclature:

  • load: Sum of all current virtual smart meter measurements per time step
  • demand: Sum of the positive current virtual smart meter measurements per time step
Column name Description
Timestep The time step ID of the current record
Per substation YYYY
   YYYY_resident_load_kW Sum of residential load in kW of all residential buildings connected to substation YYYY
   YYYY_resident_demand_kW Sum of residential demand in kW of all residential buildings connected to substation YYYY
   YYYY_demand_wo_BESS_or_selfcons_kW Sum of total demand (without BESS) or the consideration of the self-consumption of PV or wind or CHP generation in kW of all buildings (not only the residential ones) connected to substation YYYY
total_residential_load Total residential load (i.e., the sum of all virtual smart meter readings) in kW
total_residential_demand Total residential demand (i.e., only the sum of positive virtual smart meter readings) in kW
total_other_demand_kW Total non-residential demand (i.e., only the sum of positive virtual smart meter readings) in kW

XXXX-CU-time-series.csv or YYYY-AllCUs-ts.csv

Column name Description
Timestep The time step ID of the current record
ControlUnitID The control unit ID of the current record
Load_vSmartMeter_kW The power at the virtual smart meter in kW (positive values denote a demand, negative values denote a feed-in)
Load_rSmartMeters_kW The power summed over all real smart meters in kW (positive values denote a demand, negative values denote a feed-in)
Load_self_produced_kW The self-produced power that is consumed in the current time step in kW at the given unit - Please note: If excess power was fed into the battery in the previous steps, this will only be taken into account at the moment of discharge
PVFeedin_simulated_kW The current PV production in kW (if present, else 0.0)
BS_SOC The state of charge of the connected battery (if present, else 0.0)
BS_load_kW The current power of the battery storage in kW (if present, else 0.0; positive values denote battery charging, negative values denote discharging)
HP_load_kW The current power of the heat pump in kW (if present, else 0.0)
CS_load_kW The current power of the EV charging station in kW (if present, else 0.0)
CS_n_EVs_conn The number of home-parking vehicles that are currently connected to the charging station
CS_n_EVs_not_conn The number of home-parking vehicles that are currently not connected to the charging station

metrics-per-ev.csv

Column name Description
CarID The ID of the car as defined in the input data
Driving distance [km] The total distance the EV is driven in the simulation in km
E used for driving [kWh] The sum of electric energy required by the car in the simulation in kWh
Home-charged E [kWh] The sum of electric energy that has been charged at home in kWh. Can be higher than E used for driving [kWh], especially in the case of bidirectional charging
Home-discharged E [kWh] The sum of electric energy that has been discharged from the EV battery at home in kWh (only important for the case of bidirectional charging)